ALLNET Point-to-Point Coax 8 Port Master Chassis/Amplifier EOC 100 without modules incl. power supply "ALL-GHN108M-Coax-200"

ALLNET Point-to-Point Coax 8 Port Master Chassis/Amplifier EOC 100 without modules incl. power supply "ALL-GHN108M-Coax-200"
product pictures similar, may differ from the product description!

net price plus shipping costs

This product is not available at the moment. Delivery time upon request.

Due to the holiday "1. Weihnachtstag" your order will not be dispatched until the next working day.
ALLNET Point-to-Point Coax 8 Port Master Chassis "ALL-GHN108M-Coax-200" without modules The... more
Product information "ALLNET Point-to-Point Coax 8 Port Master Chassis/Amplifier EOC 100 without modules incl. power supply "ALL-GHN108M-Coax-200""

ALLNET Point-to-Point Coax 8 Port Master Chassis "ALL-GHN108M-Coax-200" without modules

The distribution amplifier ALL-GHN108M-Coax is a highly integrated solution to provide a Gigabit network on 8 coaxial lines. Up to 8 G.hn modems deliver 750 Mbit or 1700 Mbit net per coaxial strand, depending on the model. A built-in power meter simplifies service during and after installation. Without compatibility to a cable network operator, even up to 1700 Mbit is available. Signal strength and skew can be digitally adjusted. If compatibility with a cable network operator is required, 750 Mbit are available. The ALL-GHN108M-Coax-200 takes care of all tasks such as filling, amplifying and splitting the TV signals as well as inserting the G.hn network data. Elaborate mounting boards / installations are not necessary.

The chassis are available for EOC-Ethernet over COAX with 100MHz modules for DVB-C coexistence and as 200MHz with more bandwidth without DVB-C coexistence. Or explained differently.

The EOC 100 and EOC 200 differ as follows:

EOC 100 1 Gbit/650 Mbit (gross/net) see (Part No. 193132)

EOC 200 2 Gbit/1.7 Gbit (gross/net) see (Part No. 221624)

EOC 100 and EOC 200 - What's behind them !

The EOC 100 uses the frequency band 2-87 MHz for the transmission of data and can provide the broadband cable signal (DVB-C) from 88 to 860 MHz, so that the cable connection of your provider can still be fully used.

The EOC 200 uses a frequency band of 2-199 MHz. Ideal for operators of a headend

.

Technische Daten

ALL-GHN108M-Coax-200

  • Gain 33 dB (internal 48 dB)
  • Bandwidth 1.5 GHz
  • Ripple 1.5 dB
  • Integrated amplifier 125 dBµV
  • Noise figure 4 dB
  • Noiseflor -170 dBm/Hz
  • Integrated 8-fold splitter
  • 8 outputs with max. 108 dBµV
  • Return channel lock
  • High pass and low pass filter
  • Up to 8 G.hn modules
  • Internal performance meter 50 dbµV to 110 dbµV
  • Up to 64 participants/EOC1700
  • Remote power supply 24 V up to 40 EOC1700
  • Digitally adjustable:
    • 8x 31dB attenuator (0.5 dB steps)
    • skew correction (0-3-6-9 dB)

Important: setting the output power

The total band power (approx. 90 transponders) is 19.5 dB higher compared to the output power of a single transponder determined with a measuring device!

You must take this into account when adjusting the total band power.

Example 1

1 transponder:
80.0 dBµV measured
90 transponders:
99.5 dbµV tape power

The LED display on the device shows 99 dBµV.

Result: The input signal can be amplified (only) by 10 dB.

Example 2

1 transponder:
90.0 dBµV measured
90 transponders:
109.5 dbµV tape power

The LED display on the device shows 109 dBµV.

Result: The input signal cannot be further amplified.

Consideration for 5 in-wall sockets in the line:

  • Good TV reception requires 60 dbµV - 75 dbµV at the input.
  • One in-wall socket EOC 1000/EOC 2000 has a transmission loss of 2-3 dB and a decoupling loss of 18 dB.
  • The AMP X8 delivers a maximum of 110 dbµV per strand.

After 5 EOC 1000/EOC 2000 in-wall sockets connected in a row is the total attenuation:

4x3
dB
Transmission loss
+
18
dB
Decoupling attenuation
+
4x1-2
dB
Attenuation in the coaxial cable
=
34-38
dB
Total attenuation

Then an optimal setting on the ALL-GHN108M-Coax-200 would be:
60 bµV-65 dbµV + 38 dB = 98-103 dbµV.

At the first in-wall socket, 12 dB would then arrive at the output, i.e. 72-77 dbµV.